73 research outputs found

    Construction and evaluation of cysteine selective electrodes for FIA analysis of pharmaceuticals

    Get PDF
    A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%

    Determination of ametryn in soils via microwave-assisted solvent extraction coupled to anodic stripping voltammetry with a gold ultramicroelectrode

    Get PDF
    An extraction-anodic adsorptive stripping voltammetric procedure using microwave-assisted solvent extraction and a gold ultramicroelectrode was developed for determining the pesticide ametryn in soil samples. The method is based on the use of acetonitrile as extraction solvent and on controlled adsorptive accumulation of the herbicide at the potential of 0.50 V (vs. Ag/AgCl) in the presence of Britton-Robinson buffer (pH 3.3). Soil sample extracts were analysed directly after drying and redissolution with the supporting electrolyte but without other pre-treatment. The limit of detection obtained for a 10 s collection time was 0.021 µg g-1. Recovery experiments for the global procedure, at the 0.500 µg g-1 level, gave satisfactory mean and standard deviation results which were comparable to those obtained by HPLC with UV detection

    Extracção assistida por microondas de pesticidas em produtos agrícolas

    Get PDF
    Tese de Mestrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 200

    Analysis of PCBs in soils and sediments by microwave-assisted extraction, headspace-SPME and high resolution gas chromatography with ion-trap tandem mass spectrometry

    Get PDF
    A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs

    Development and validation of a novel method for the analysis of chlorinated pesticides in soils using microwave-assisted extraction–headspace solid phase microextraction and gas chromatography–tandem mass spectrometry

    Get PDF
    A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples

    Anthropogenic contamination of Portuguese coastal waters during the bathing season: Assessment using caffeine as a chemical marker

    Get PDF
    Bathing water quality standards are based on international standards and legislations. However, in Europe, only the microbiological parameters are to be accomplished. Recent research has focused on chemical indicators that can determine human fecal contaminants in water. Therefore, the suitability of caffeine as a chemical marker of seawater pollution in the north Portuguese coastal area in the Atlantic Ocean during the bathing season was assessed in this study. The quality of water from the coasts of five cities was monitored. 101 seawater samples were collected from 14 beaches, and their water quality was classified as sufficient, good, and excellent. Caffeine was detected in all samples in concentration range of 18 to 525ng/L. The highest average concentration of caffeine was found in seawater samples collected in July from beaches classified as having sufficient water quality, which were located in cities with high population density and high tourist affluence.info:eu-repo/semantics/publishedVersio

    Determination of total petroleum hydrocarbons in soil from different locations using infrared spectrophotometry and gas chromatography

    Get PDF
    Total petroleum hydrocarbons (TPH) are important environmental contaminants which are toxic to human and environmental receptors. Several analytical methods have been used to quantify TPH levels in contaminated soils, specifically through infrared spectrometry (IR) and gas chromatography (GC). Despite being two of the most used techniques, some issues remain that have been inadequately studied: a) applicability of both techniques to soils contaminated with two distinct types of fuel (petrol and diesel), b) influence of the soil natural organic matter content on the results achieved by various analytical methods, and c) evaluation of the performance of both techniques in analyses of soils with different levels of contamination (presumably non-contaminated and potentially contaminated). The main objectives of this work were to answer these questions and to provide more complete information about the potentials and limitations of GC and IR techniques. The results led us to the following conclusions: a) IR analysis of soils contaminated with petrol is not suitable due to volatilisation losses, b) there is a significant influence of organic matter in IR analysis, and c) both techniques demonstrated the capacity to accurately quantify TPH in soils, irrespective of their contamination levels

    Determination of carbamate and urea pesticide residues in fresh vegetables using microwave-assisted extraction and liquid chromatography

    Get PDF
    An analytical multiresidue method for the simultaneous determination of seven pesticides in fresh vegetable samples, namely, courgette (Cucurbita pepo), cucumber (Cucumis sativus), lettuce (Lactuca sativa, Romaine and Iceberg varieties) and peppers (Capsicum sp.) is described. The procedure, based on microwave-assisted extraction (MAE) and analysis by liquid chromatography– photodiode array (LC–PDA) detection was applied to four carbamates (carbofuran, carbaryl, chlorpropham and EPTC) and three urea pesticides (monolinuron, metobromuron and linuron). Extraction solvent and the addition of anhydrous sodium sulphate to fresh vegetable homogenate before MAE were the parameters optimised for each commodity. Recovery studies were performed using spiked samples in the range 250–403 µgkg- 1 in each pesticide. The pesticide residues were extracted using 20mL acetonitrile at 60 ºC, for 10 min. Acceptable recoveries and RSDs were attained (overall average recovery of 77.2% and RSDs are lower than 11%). Detection limits ranged between 5.8 µgkg- 1 for carbaryl to 12.3 µgkg- 1 for carbofuran. The analytical protocol was applied for quality control of 41 fresh vegetable samples bought in Oporto Metropolitan Area (North Portugal). None of the samples contained any detectable amounts of the studied compounds

    Chlormequat selective electrodes: construction, evaluation and application at FIA systems

    Get PDF
    A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%

    Monitoring survey of caffeine in surface waters (Lis River) and wastewaters located at Leiria Town in Portugal

    Get PDF
    Investigation during 11-month period was performed to study the presence of caffeine in the Lis River in Leiria Town in Portugal, and a monitoring during 9-month period was realized to check the contribution of the human pollution of two wastewater treatment plants (WWTPs) that discharge their effluents to the studied river. The samples were collected in five sampling points along the river and in two influents and two effluents of the studied WWTPs. Caffeine was detected in all ninety-one collected samples. The caffeine concentration ranged from 25.3 to 321 ng/L in the river samples, from 112 to 1927 ng/L in the WWTP effluents, and from 9478 to 83,901 ng/L in the WWTP influents. The highest concentration in the river was detected in the two sampling points located after the effluent discharge points and reached 315 and 321 ng/L. Risk assessment was performed for three trophic levels using the risk quotient calculation and revealed that caffeine do not cause toxic effect on Daphnia magna and on fish but could be possibly toxic to algae. The results proved that caffeine can be an effective indicator of human-born pollution.The authors received funding from the EU and FCT/UEFISCDI/FORMAS for funding, in the frame of the collaborative international consortium REWATER financed under the ERA-NET Cofund WaterWorks2015 Call. This ERA-NET is an integral part of the 2016 Joint Activities developed by the Water Challenges for a Changing World Joint Programme Initiative (Water JPI). This work was also supported by UID/QUI/50006/2019 with funding from FCT/MCTES through national funds.info:eu-repo/semantics/publishedVersio
    corecore